Call now – (02) 9586 3111

DA vs CC access report in NSW: what changes and why you cannot reuse the DA report

Can you attach the Development Application access report to the Construction Certificate package? Generally no. A DA report shows the design is capable of meeting access requirements for consent. A CC report verifies the detailed construction drawings and specifications so a registered certifier can issue a certificate. Same project. Different purpose, different drawings, different language.

This page is the comparison. For lodgement-ready DA, CC and CDC reports, use the access reports for DA, CC and CDC page.

Quick answer: can I use my DA access report for the Construction Certificate?

Generally no. A report prepared for development consent is not suitable as the access documentation for CC lodgement. Certifiers typically need an assessment of the CC drawing set against the Disability (Access to Premises - Buildings) Standards 2010 (Premises Standards), the access provisions of the National Construction Code in force in NSW, and referenced Australian Standards such as AS 1428.1:2021. Re-lodging the DA PDF is a common reason for an RFI.

A DA-issued access report is not a CC report. If the consent or the certifier calls up verification at CC, commission a CC-stage report on the current construction documents.

Side-by-side: DA access report vs CC access report

Item DA access report CC access report
Purpose Capability for development consent Verification of detailed construction documents for the certificate
Who relies on it Council planners and the design team Registered certifier / PCA and the builder
Drawing depth Planning / DA set Construction drawings and specifications
Compliance language Capable of compliance; items to resolve at CC Compliant, capable subject to a stated detail, non-compliant, or insufficient information
Fittings and finishes Often incomplete Must be assessable: doors, sanitary layouts, ramps, TGSI, parking, lifts
Reuse Not suitable as the CC report Tied to the CC documents listed; revise if the set changes

Development Application access report

A DA report supports the SEE and planning package. It tests path of travel, entries, lifts, ramps, parking, sanitary facilities and any adaptable or livable-housing overlay in the DCP or Housing SEPP. Planning sets rarely include door schedules, sanitary set-outs or luminance contrast. Reports lodged through the NSW Planning Portal routinely leave fittings and full construction compliance to CC. Many DA reports state they are not to be used for a Construction Certificate.

Construction Certificate access report

A CC report assesses the documents the builder will build from. Those documents must not be inconsistent with the consent. The certifier needs elemental status and actions, and a statement of compliance scoped to that drawing revision. City of Newcastle-style CC checklists request an appropriately qualified access consultant report at lodgement for some classes (for example Class 1b boarding houses). That is checklist practice, not a claim that every Class 1a house needs the same report.

Why certifiers reject a DA access report at CC

What detail is required at CC stage

For the full contents checklist certifiers can share, see what certifiers want in a disability access report. If Deemed-to-Satisfy cannot be met, use a Performance Solution rather than stretch a DtS claim.

What to do next

Engage for a CC-stage access report on the construction set. Do not re-lodge the DA PDF. Send door and sanitary schedules, ramp and stair geometry, lift specifications if available, parking dimensions, the stamped consent and access-related conditions. A previous DA report is useful background. It is not the CC assessment.

CDC reports sit closer to CC than to a light DA capability statement. Detail lives on the DA, CC and CDC lodgement page.

GJ Finn & DW Wong trading as Sydney Access Consultants prepare both stages in New South Wales. Work is based in Hurstville. On the Mid North Coast, Sandy Grey works from Black Beach. In Western Australia the same report discipline is applied against the code in force there. See locations.

Ask about a CC-stage report on (02) 9586 3111.

Frequently asked questions

Can I use my DA access report for a Construction Certificate in NSW?

Generally no. A DA report supports planning consent. A CC is assessed on detailed construction drawings and specifications. Re-lodging a DA-stage report usually does not meet that expectation and can trigger RFIs or delay.

What is the difference between a DA access report and a CC access report?

A DA report focuses on spatial capability so council can grant consent. A CC report checks the documents the builder will use, confirms consistency with consent, and records clear compliance status for access elements. Same standards family. Different purpose, drawing depth and language.

Why did the certifier reject our DA access report?

Common reasons: less-developed drawings; “capable of compliance” language; unresolved fittings and dimensions; design change since consent; or a condition / checklist that requires CC-stage verification. The remedy is a CC-stage report on the current set.

Do DA consent conditions always require a new access report at CC?

Not always. Some conditions and some checklists do. Many certifiers still request one because the DA report cannot verify the CC documents. Treat a new CC report as the safe assumption once detailed drawings exist.

What if we have multiple Construction Certificates?

Each report should match the scope of the CC being sought. Do not sign off access work that sits in a later stage as if it were complete.